First we need to enable detailed logging in FLOW Automation. On the node that is running the FLOW Automation service run the following: Note - this will restart all the FLOW services on the node
flow-setting set automation scriptrunner/debug true
flow-restart
You should now trigger your Automation template again and observe the following log file:
/var/log/flow/flow-automation.log
Send the log to EditShare support along with a JSON export of the Automation template.